| Customization: | Available |
|---|---|
| After-sales Service: | Engineers Available to Service Machinery Overseas |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| 1. Covers an area of ~600m2 |
| 2. The highest point of the equipment <8m |
| 3. Product oxygen flow ≥ 1800Nm3/Hr |
| 4. Oxygen purity ≥ 93%±2% |
| 5. Oxygen supply pressure ≥ 1barg |
| 6. Annual operating rate > 98% |
| 7. The energy consumption of oxygen production is 0.3KW.h/Nm3±0.02 (including the compressed oxygen part) |
| 8. 85 decibels 1 meter outside the equipment noise boundary |
| 9. Installed capacity 670KW 220V 60HZ Blower (using the raw material gas provided by the customer) Vacuum pump 560KW Oxygen compressor 110KW |
| system name | content | parameter |
| Vacuum pump sealing water | flow | 3m3/Hr |
| temperature | <32ºC | |
| Water quality (soft water) | <30mg/L (CaO), suspended matter: 5mg/L, pH value: 6~9 | |
| pressure | >0.2Mpa sent to the water inlet of water equipment | |
| Vacuum pump cooling water | flow | 4m3/Hr |
| temperature | <32ºC | |
| Water quality (soft water) | <560mg/L (CaO), PH value: 6~9 | |
| pressure | >0.3Mpa sent to the water inlet of water equipment | |
| Oxygen compressor cooling water | flow | air-cooled |
| temperature | ||
| water quality | ||
| water quality | ||
| pressure |
| Instrument air for butterfly valve | quality | Dry, clean instrument air or inert gas |
| flow | 180m3/Hr | |
| dew point temperature | -40ºC | |
| Dust particle size | Not more than 0.3μm | |
| pressure | 0.4~0.7Mpa sent to the air bag (sub-cylinder) | |
| power requirements | Voltage | 380V |
| Installed capacity | 539KW sent to the equipment receiving cabinet | |
| Civil plant | The project is designed outdoors without the client providing a factory building. | |
| Equipment basis | Construction according to drawing requirements | |