Our Hydrogen Fuel Cell power stations adopt modular and hierarchical designs based on functional requirements, safety requirements and site conditions. Starting from functional requirements such as power generation, gas supply, energy distribution, and control, we carry out sub-system design. Through the analysis and comparison of the technical routes of the sub-systems, the final optimal implementation path is determined.
The specific functions of the power station are as follows:
Power supply: Provide stable AC output
Output transformation: adjust output power according to power demand
Early warning protection: It has early warning protection function for fuel leakage, under-voltage, over-voltage, overload, over-temperature and other fault conditions.
Self-maintenance: can charge the battery and perform self-maintenance
Grid-connected output: Grid-connected output.
Typical parameters for 1MW Hydrogen Fuel Cell Power Station | ||
Items | Specific parameters | Remark |
Installed capacity | 1MW | |
Grid-connected power | 796kW | Net output |
The output voltage | 10kV | Design on demand |
Output current | ≤100A | Design on demand |
Output frequency | 50HZ | |
Input voltage | 380VAC | |
Work noise | ≤80dB | |
Working temperature | -10ºC~+40ºC | Self heating |
Storage limit temperature | -25ºC~+45ºC | |
Relative humidity | ≤95% | 40ºC |
Service life | ≥30000h | |
Covered area | 300m 2 | Design on demand |
Protection level | IP54 | |
Working altitude | ≤2000m |
Hydrogen requirement
The pipeline hydrogen comes from the buffer tank outlet after purification by PSA system. The design parameters of hydrogen are shown in the table below: |
|||||
Medium |
Operation pressure
|
Design pressure
|
Operation temperature
|
Design temperature
|
Purity
|
Mpa.g
|
Mpa.g
|
ºC
|
ºC
|
%
|
|
Hydrogen
|
≥1
|
1.3
|
Normal temperature
|
60
|
99.99
|
Cooling water requirement
Open cooling water system for hydrogen fuel cell power generation unit the design parameters of the cooling water system are: |
||||
Medium |
Operation pressure
|
Design pressure
|
Operation temperature
|
Design temperature
|
Mpa.g
|
Mpa.g
|
ºC
|
ºC
|
|
Cooling water supply
|
0.25
|
0.5
|
32
|
50
|
Cooling water return
|
0.1
|
0.5
|
32
|
50
|
Our products are produced in accordance with international standards, and the production process has strict quality control and inspection procedures, and all products are qualified products.